  • D40P-4(1).jpg

D40P-4 Dia.40mm Ceramic Cartridge Series


1. Maximum Opening Angle: 23° 2. Maximum Turning Angle: 100° 3. Maximum Operating Temperature: 90°C; 4. Locking Torque: 10~12N. m; 5. Breaking Torque of Cartridge Stem: ≥15N. m;


Classification:


key word:


  • DESCRIPTION
  • Technical Data: Test items:
    1. Maximum Opening Angle: 23° 1. Blasting Test:
    Hydrostatic pressure 3.5MPa, no deformation
    2. Maximum Turning Angle: 100° 2. Factory Seal Test:
    Hydrostatic pressure 18~25bar
    Dynamic water pressure 4~10bar
    3. Maximum Operating Temperature: 90°C; 3. Factory Torque Test:
    When the static pressure is zero, the turning torque is 0.3~0.5N.m, and the switching torque is 0.3~0.5N.m
    4. Locking Torque: 10~12N. m;  
    5. Breaking Torque of Cartridge Stem: ≥15N. m;  

     

     

     

     

    Pressure and Average Flow

    P(bar)

    0.5

    1

    1.5

    2.0

    2.5

    3.0

    3.5

    4.0

    4.5

    F(l/min

    14

    20

    22.5

    25

    26.5

    29

    30

    31.5

    33

Want to learn more about the protuct?